Simply Wholesale Tripp Lite

Tripp Lite Single Phase Hot Swap Pdu 2U Rack Mount

GET DEAL NOW

TRIPP LITE SINGLE PHASE HOT SWAP PDU 2U RACK MOUNT FEATURES Tripp Lite Hot-swap PDU systems support live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loads This is universally compatible with any Tripp Lite or other brand of 200-240V UPS rated 2000 to 3000VA with a C20 input cable 2U horizontal rackmount form factor compatible with 2 or 4 post racks Supports space saving rear-post mounting in the same rack space as many Tripp Lite Rackmount UPS systems (select installations, see manual) Pair of detachable PDU input cables connect to separate Utility and UPS power sources (2 5-ft. (1.52 m) C19-C20 and 2 6-ft. (1.83 m) C13-C14 interconnect cables included - user supplied alternate cabling supported) 6 C13 and 2 C19 outlets support critical networking loads in both Utility and UPS operating modes One additional C19 pass-through outlet supports UPS input power cord Dual input power cables support PDU connection to separate Utility and UPS power sources Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS Set the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPS Set the switch to Utility to bypass the UPS and provide connected equipment with unfiltered power directly from the Utility line cord while the UPS system is removed and replaced with a fresh one Once the new UPS is up and running with all connection s restored, set the switch back to the UPS setting to once again provide fully-conditioned UPS power to connected equipment SPECIFICATIONS Brand: Tripp Lite PDU Type Hot-Swap Input PDU Input Voltage 200-240V Recommended Electrical Service Works with 200-240V UPS systems with C20 compatible input cabling Maximum Input Amps 16 Input Connection Type UTILITY & UPS inputs are available from separately labeled C20 inlets, compatible with included C19-C20 interconnect cables or with compatible user-supplied cabling PDU Plug Type IEC-320 C20 Input Phase Single-Phase Input Cord Length (m) 1.83 Output Output Watt Capacity (Watts) 3680 Output Capacity Details 3.84kW (240V), 3.68kW (230V), 3.52kW (220V), 3.33kW (208V), 3.2kW (200V) / 16A total capacity; 16A max per C19 outlet; 12A (10A CE) max per C13 outlet Frequency Compatibility 50 / 60 Hz Output Receptacles (6) C13; (3) C19 Output Nominal Voltage 200-240V USER INTERFACE, ALERTS & CONTROLS Front Panel LEDs Lighted indicators confirm UPS and Utility switch position and operating mode Switches Manual 2 position transfer switch offers fast switching between UPS and Utility operating modes in less than 6 milliseconds Physical Form Factors Supported 2U rackmount in 2 or 4 post racks Material of Construction Steel Minimum Required Rack Depth (cm) 24.13 PDU Form Factor Horizontal (2U) Shipping Dimensions (hwd / cm) 30.99 x 15.75 x 51.31 Shipping Weight (kg) 4.54 Unit Dimensions (hwd / cm) 8,7 x 44 x 7,7 Unit Weight (kg) 3.49 Environmental Operating Temperature Range 0C ~ 40C (32F ~ 104F) Storage Temperature Range -30°C to +50°C (-22°F to +122°F) Relative Humidity 5-95% non condensing Operating Elevation (ft.) 0-10,000 Operating Elevation (m) 0-3000 Standards & Compliance Certifications Tested to UL60950 (USA), CSA (Canada), CE (IEC60950) PACKAGE CONTENTS 1 x Tripp Lite Single Phase Hot Swap Pdu 2U Rack Mount

SKU : 39358627086387

GET DEAL NOW

Categories: